TITLE Laboratory baffled-column flotation of mixed Campbell Eagle seam bituminous coal 
SUMMARY ... (20- by 25-cm) rod ... Figure 5 - Grade-weight recovery performance of the laboratory-
scale column ... The first test condition had a feed rate of 0.61 L/min at 5.0 ...
AUTHOR Eisele, T. C. ; Rao, T. C. ; Ripke, S. J. ; Shoop, K. J.
PUBLISHED 1999
TITLE Implementation Of The Hydrofloat Technology At The South Fort Meade Mine 
SUMMARY ... BPL R e cov e ry ( % ) Plant Testing Laboratory Testing Figure 4. Ultra-Coarse Pilot-
and Lab-Scale Results. ... 15 20 25 30 35 40 P r o duct I n so l G r ade ( ...
AUTHOR Kohmuench, J. ; Mankosa, M. ; Kennedy, D. ; Yasalonis, J. ; Taylor, G. ; Luttrell, G.
PUBLISHED 2007
TITLE Color Measurements Of Minerals And Mineralized Froths 
SUMMARY ... Initial color measurements weredone in the laboratory using binary mixtures of dry
minerals. ... L 1 ( 1 I 6 5 I I I I 20 40 60 80 J 100 MoS ... " 0 5 10 15 20 25 30 35 ...
AUTHOR Gebhardt, J. E. ; Tolley, W. K. ; Ahn, J. H.
PUBLISHED 1994
TITLE Design criteria and recent developments in large-capacity Wemco flotation cells 
SUMMARY ... 3-Wemco laboratory cell with I+ I parts ... P =net power consumption g =gravitational
acceleration l =fluid density ... the rotor and the tip speed by about 25 per cent ...
AUTHOR Kind, P.
PUBLISHED 1976
TITLE Sonic Flotation of Phosphate Ores 
SUMMARY ... same fashion as the conventional laboratory flotation tests. ... 1012) to a concentration
of 25 ppm frother ... Mixing chamber #l gave much higher phosphate recoveries ...
AUTHOR Jordan, C. E. ; Scheiner, B. J.
PUBLISHED 1989
TITLE Process Mineralogy – A New Generation For Ore Characterization And Plant Optimization 
SUMMARY ... taken back to the polished sec- tion preparation laboratory and was ... 23-25, Denver,
Colorado ... Lotter, NO, Whittaker, PJ, Kormos, L, Stickling, JS, and Wilkie, GJ ...
AUTHOR Baum, W.
PUBLISHED 2004
TITLE Recovery of additional tungsten from Climax byproduct-plant tailing 
SUMMARY ... L ... Climax was obtained and tested on the laboratory table to establish its laboratory
operating conditions ... A feed rate of 11.4 kg/h (25 lb per hr) and a tilt of ...
AUTHOR Malhotra, D. ; Burrer, G. E. ; Irwin, T. E. ; Johnson, S.
PUBLISHED 1987
TITLE Graphic Routine And Digital Simulation The Aids In Prediction Of Coal Preparation Plant Performance And Yield Optimization 
SUMMARY ... Two typical laboratory time-yield profiles tested under different flotation conditions
are illustrated ... L I ... Y = Output = f (21, 22, 23, 24, 25, 26, 27, 28) XX ...
AUTHOR Peng, Felicia F.
PUBLISHED 1983
TITLE Hydrodynamic Effects In Flotation Of Ores 
SUMMARY ... saturated lime water for 1 h in a laboratory rod millat ... was added to raise the frother
concentration to 25 ppm (0.075 g ... 5 min at 1,000 r/mln with 2.25 L/min of ...
AUTHOR Scheiner, B. J. ; Jordan, C. E.
PUBLISHED 1989
TITLE Magnetic Field Application In Cationic Silica Flotation Of Magnetic Taconite Concentrates 
SUMMARY ... in cationic silica flotation using a Denver laboratory flota- tion ... was added to the
level of 830 L (220 gal ... density in the flotation cell became about 25% solids ...
AUTHOR Ersayin, S. ; Iwasaki, I.
PUBLISHED 2003
Showing: 1 to 10 of 991 matches for "Laboratory 25 L flotation test Unit"  Page   1   2   3   4   5   6   7   8   9  next